Specifications
Block Format: | Interchangeable |
---|---|
Capacity: | 1 x 96-well plate |
Detection Method: | Primer-Probe Detection, SYBR |
Dimensions: | 53.3 cm (21 in) (W) x 63.5 cm (25 in) (D) x 64.5 cm (25.4 in) (H) |
Dynamic Range: | Up to 9 logs of linear dynamic range |
For Use With (Equipment): | ViiA™ 7 System |
Format: | 96-well plate |
Green Features: | Energy efficient, Fewer resources used, Less waste |
High Throughput Compatibility: | High Throughput-Compatible, Multiplexing |
Input Voltage: | 100-240 V |
Optics: | 6 emission filters (500-720 nm), 6 excitation filters (450-670 nm), OptiFlex™ System (enhanced fluorescence detection) |
Other Format Options: | 384-well Block Upgrade Option, 96-well Fast Block Upgrade Option, TaqMan® Array Card Block Upgrade Option |
Plate Handling: | Automation includes plate-loading arm with barcode, Optional automation accessory robot |
Power Limit: | 60 Hz |
Product Size: | 1 instrument |
Program Features: | Remote monitoring of up to 15 instruments |
Reaction Speed: | Standard |
Reaction Volume Range: | 10-100 µl |
Resolution: | Detects as little as 1.5-fold changes in target quantities (in singleplex reactions) |
Run Time: | About 35 min. (varies depending on reagents and other factors) |
Sensitivity: | Down to 1 copy |
Temperature Range (Metric): | 4-100°C |
Temperature Uniformity: | ±0.5°C |
Weight: | 60.7 kg (134 lb) |
Quantstudio Viia 7 Software Machine
JavaScript must be enabled in order to use this site.
Please enable JavaScript in your browser and refresh the page.
The software is compatible with data files for the following real-time PCR instruments:
QuantStudio™ 7 Pro Real-Time PCR System (including TaqMan™ Array Card format)
QuantStudio™ 6 Pro Real-Time PCR System
QuantStudio™ 5 Real‑Time PCR System (if the plate file for the instrument run is created using QuantStudio™ Design and Analysis v2)
QuantStudio™ 3 Real-Time PCR System (if the plate file for the instrument run is created using QuantStudio™ Design and Analysis v2)
QuantStudio™ 1 Real-Time PCR System (if the plate file for the instrument run is created using QuantStudio™ Design and Analysis v2)
Quantstudio Viia 7 Software Mac Version
Applied Biosystems StepOne Manual Online: Perform A Background Calibration. Materials Required Calibration Guidelines Purpose of the Calibration Notes 94 Perform a background calibration monthly. ViiA™ 7 System: Format: 96-well plate: Green Features: Energy efficient, Fewer resources used, Less waste: High Throughput Compatibility: High Throughput-Compatible, Multiplexing: Input Voltage: 100-240 V: Optics: 6 emission filters (500-720 nm), 6 excitation filters (450-670 nm), OptiFlex™ System (enhanced fluorescence detection) Other.
Data files for the following instruments are a legacy file format that can be opened in the software, but can only be saved as the updated file format:
QuantStudio™ 5 Real‑Time PCR System (if the plate file for the instrument run was not created using QuantStudio™ Design and Analysis v2)
QuantStudio™ 3 Real-Time PCR System (if the plate file for the instrument run was not created using QuantStudio™ Design and Analysis v2)
QuantStudio™ 1 Real-Time PCR System (if the plate file for the instrument run was not created using QuantStudio™ Design and Analysis v2)
QuantStudio™ 6 Flex Real-Time PCR System
QuantStudio™ 7 Flex Real-Time PCR System (including TaqMan™ Array Card format)
QuantStudio™ 12K Flex Real–Time PCR System (except OpenArray™ format)
StepOnePlus™ Real-Time PCR System
ViiA™ 7 Real-Time PCR System
7500/7500 Fast Real-Time PCR System
7900HT Real-Time PCR System
Quantstudio Mac
Note: To convert a legacy data file into the updated file format, open the data file, then click Actions > Save As.